Ductile Iron vs Cast Iron | Eng-Tips

Author: Heather

Jun. 30, 2025

1 0 0

Ductile Iron vs Cast Iron | Eng-Tips

bimr

Civil/Environmental
Joined
Feb 25,
9,378
Location
US
Cast iron pipe was historically used as a pressure pipe for transmission of water, gas and sewage, and as a water drainage pipe during the 19th and 20th centuries. It comprises predominantly a gray cast iron tube and was frequently used uncoated, although later coatings and linings reduced corrosion and improve hydraulics. Cast iron pipe was superseded by ductile iron pipe, which is a direct development, with most existing manufacturing plants transitioning to the new material during the s and s.

Cast iron pipe is still used in some DWV applications, not in pressure applications.

What is your application? Upvote 0 Downvote

bridgebuster

Active member
Joined
Jun 27,
3,970
Location
US
Wait a minute. If the contractor bid on DI then tell him you want DI. If he put CI in the ground too bad, he can rip it out and put in what was bid. Upvote 0 Downvote

rconner

Civil/Environmental
Joined
Mar 18,
1,733
Location
US
You do not note the specific application for the pipe involved. While gray cast iron pipe has a formidable performance record in many areas and for many applications, gray cast iron pipe has not been manufactured for water pipe applications in the USA since the late 's. This was due to the advent of ductile iron, that has approximately twice the strength and many times the toughness and ductility of the gray cast iron. Due to very similar chemical analysis and pipe manufacturing methods manufacture ductile iron has comparable corrosion resistance to the former gray cast iron, and when furnished with modern and correctly applied corrosion protection systems such as loose polyethylene encasement ductile iron can generally be expected to perform even better. Gray cast iron is not an equal to modern ductile iron pipe. Upvote 0 Downvote

DTOREC

Mechanical
Joined
Dec 4,
27
Location
US
I'd be wary that the contractor is trying to save some coin at the expense of performance. DI way outperforms CI, but it's also more expensive. A good "tell" will be when you tell him no, stick with CI. If he starts gyrating in all sorts of conniptions and starts pleading, that means he either wanted to save some money, or they ordered CI instead of DI, or they bid CI instead of DI. Upvote 0 Downvote

cvg

Civil/Environmental
Joined
Dec 16,
6,868
Location
US
materials cost difference is not great, most of the cost is labor and equipment to install. I would not see any benefit to using cast iron for underground piping (assume it is underground). for interior drain and waste pipe, I see no problem with using cast iron. Upvote 0 Downvote

martin

Civil/Environmental
Joined
Jun 15,
157
Location
US
The application here is just 4" storm laterals from large proccess vaults. Very little water will ever even reach them. I dont think its a big issue as far as cost and installation. The pipe will be coated inside and out. I am not that familiar with cast iron so any info is helpful Upvote 0 Downvote

rconner

Civil/Environmental
Joined
Mar 18,
1,733
Location
US
I wonder if what the contractor is trying to substitute is "cast iron soil pipe" (CISP)? If so, in addition to lesser beam etc. strength CISP may not be furnished also with cement mortar lining, like what typically comes inside often stocked ductile iron piping. Cement lining is generally also more durable than bituminous linings,and does not typically result in internal tuberculation/build-ups in even some aggressive water exposures. Upvote 0 Downvote

martin

Civil/Environmental
Joined
Jun 15,
157
Location
US
Anyone know why Cast Iron pipe is made hub-less instead of a bell and spigot type installation? I dont really see the benefit of a hubless pipe and coupling constrcution. Upvote 0 Downvote

bimr

Civil/Environmental
Joined
Feb 25,
9,378
Location
US
The cast iron pipe that you are asking is normally installed for sewers and building DWV. Bell and spigot pipe has to be installed with pipe restraints such as thrust blocks. It is not possible to install bell and spigot piping on pipe hangers. Upvote 0 Downvote

BenJohnson

Civil/Environmental
Joined
Jul 12,
52
Ductile Iron can be welded; Cast Iron cannot. Unplanned or future changes are much easier to make if you can weld on a fitting, patch, etc.

I would sit down with the contractor and discuss thoroughly why he wants to change the specs. You are using pipe in a strange situation - so he may have a good argument to use CI pipe. I am guessing money or ease of installation probably fits into the equation. (or he has a bunch of CI sitting in his storage yard he wants to get rid of). In this case, your client deserves a cut price.

99% of the time DI is superior material to use, and Cast Iron will probably not be manufactured . Upvote 0 Downvote

martin

Civil/Environmental
Joined
Jun 15,
157
Location
US
But the hubless cast iron pipe just uses couplings for pipe connctions instead of a bell and spigot. I know the difference just curious why cast iron comes hubless and the benefits of it? I really don't see any.

Do you really think future changes are easier with a weld then a simple bell and spigot connection? Upvote 0 Downvote

rconner

Civil/Environmental
Joined
Mar 18,
1,733
Location
US
I suspect in general hubless pipe, most often employing something like plain end pipes and a low-profile rubber boot and hose clamps, is probably considered a notable advance compared to e.g. formerly employed caulked (oakum etc.) bell and spigot cast iron soil pipes. I think now pipe systems are available in both sockets with compression gasket as well as hubless joining. I think hubless is used mostly for exposed, aboveground pipe systems and is also a less bulky system within wall confinements etc. While it seems straying from the original inquiry, I guess you could get more information if you are interested from the Cast Iron Soil Pipe Institute or a manufacturer like Charlotte Pipe. Upvote 0 Downvote

bimr

Civil/Environmental
Joined
Feb 25,
9,378
Location
US
Cast iron soil pipe and fittings are also used for storm drainage from roofs, yards, and courtyards in building construction. At present, cast iron soil pipe and fittings are the preferred material in high-rise structures for drain, waste and vent and sewer – without concern for building height.


Talk to a plumber about cast iron DWV systems if you want to know about hubless. Decades ago, DWV was joined with caulk and molten lead. Hubless fittings are a real time saver for plumbing of DWV systems.


Welding ductile iron pipe is problematic. I have never witnessed this welding and I don't believe that it is a common practice.

Upvote 0 Downvote